WOODWARD 5501-467 以太网/IP网络通信模式
轻松配置
5501-467 网关附带web控制台,无需安装额外的实用程序即可轻松进行配置。此外,HTTPS通信加密可确保更高的网络安全性。在大多数数据捕获应用程序中,使用Modbus命令配置设备可能会消耗时间并增加成本。MGate 5135/5435网关通过CSV文件提供脱机配置,以帮助快速完成Modbus设置。MGate网关还提供了软件-可配置的高/低拉和终端电阻设置forRS-485 2-wire以减少工作和打开机箱的需要。
轻松故障诊断
5501-467 网关提供了多种维护功能,可减少故障诊断时间和成本,包括LED指示灯、协议诊断、流量监视器和标记视图。这些工具可帮助您捕获和检查数据,以便轻松确定问题的根本原因,尤其是在安装阶段。MGate网关还具有状态监控和故障保护功能。状态监控功能会在Modbus设备断开连接或未响应时通知PLC/DCS/SCADA系统,在这种情况下,PLC/DCS会获取每个终端设备的状态,然后发出报警以通知操作员。故障保护功能在主机断开连接时执行预定义的操作,以防止终端设备长时间脱机。
功能包括
Modbus与以太网/IP之间的协议转换
以太网/IP适配器支持
RTU/ASCII/TCP客户端Modbus支持
灵活部署以太网级联和双子网
嵌入式流量监控/诊断信息便于故障诊断
通过基于web的控制台轻松配置设备
用于配置备份/复制的microSD卡
WOODWARD 5501-467 以太网/IP网络通信模式
Easy configuration
The 5501-467 gateway comes with a web console and can be easily configured without installing additional utilities. In addition, HTTPS communication encryption ensures higher network security. In most data capture applications, configuring devices with Modbus commands can consume time and increase costs. The MGate 5135/5435 gateway provides off-line configuration via a CSV file to help complete Modbus setup quickly. The MGate Gateway also offers software - configurable high/low pull and terminal resistance Settings forRS-485 2-wire to reduce the need to work and open the case.
Easy fault diagnosis
The 5501-467 gateway offers several maintenance features to reduce troubleshooting time and cost, including LED indicators, protocol diagnostics, traffic monitors, and tag views. These tools help you capture and examine data to easily determine the root cause of a problem, especially during the installation phase. The MGate gateway also has status monitoring and fail-safe functions. The condition monitoring function notifies the PLC/DCS/SCADA system when Modbus devices are disconnected or not responding, in which case the PLC/DCS obtains the status of each terminal device and then issues an alarm to notify the operator. The fault protection function performs predefined actions when the host is disconnected to prevent the terminal device from going offline for a long period of time.
Functions include
Protocol conversion between Modbus and Ethernet /IP
Ethernet /IP adapter support
RTU/ASCII/TCP client Modbus support
Flexibly deploy Ethernet cascades and dual subnets
Embedded flow monitoring/diagnostic information facilitates fault diagnosis
Easily configure devices through a web-based console
microSD card used to configure backup or replication
WOODWARD 5501-467 以太网/IP网络通信模式
WOODWARD 8237-1246 PROTECH-GII | safety |
WOODWARD 5466-258 | SIMPLEX DISCRETE I/O |
WOODWARD 8200-1501 | PEAK200 | Steam tur |
Woodward 9907-165 Controller module |
WOODWARD 9907-1200 CPC-II Current to Pre |
Woodward 9907-252 control governor Modu |
Woodward 9907-166 505 turbine control mo |
Woodward 9907-163 505 Digital Governor T |
Woodward 9907-162 505 Digital Governor S |